SHimastu蓄电池NP26-12 12V26AH

2024-11-22 08:00 111.196.210.222 2次
发布企业
山东恒泰正宇电源科技有限公司销售部商铺
认证
资质核验:
已通过营业执照认证
入驻顺企:
6
主体名称:
北京恒泰正宇科技有限公司
组织机构代码:
91110112MA0198QL6L
报价
请来电询价
品牌
SHimastu蓄电池
型号
NP26-12
产地
广东
关键词
SHimastu蓄电池,NP26-12,12V26AH,
所在地
济南市历城区银座万虹广场1001-5号
手机
13290292093
营销部经理
刘光国  请说明来自顺企网,优惠更多
请卖家联系我
13290292093

产品详细介绍

SHimastu蓄电池NP26-12 12V26AH


Shimastu电子科技有限公司,一个专用的密封铅酸(SLA)电池的专业厂家,引进日本AGM公司的技术基础。Shimastu一直在研究、开发、生产和营销SLA电池自2001年以来。采用先进的技术过程从日本技术和现代化的生产设备和检测设备,Shimastu一直为客户提供SLA的NP系列电池使用寿命长,质量可靠,性能稳定。

Shimastu Electronic Technology Co., Ltd., a dedicatedprofessional manufacturer of Sealed Lead Acid ( SLA) batteries,introducing Japan AGM technology from the company foundation.Shimastu has been researching, developing, manufacturing andmarketing SLA batteries since 2001. Adopting the advanced technicalprocess from Japan Technology and modern production machines andtesting equipment, Shimastu has been supplying customers with NPseries of SLA batteries which has long service life, good quality,reliable and stable performance.

储能多样化发展《指导意见》“开发储电、储热、储冷、清洁燃料存储等多类型、大容量、低成本、高效率、长寿命储能产品及系统”。

在能源互联网背景下,储能的意义更广,储电、储热、储冷、清洁燃料存储(例如储氢)都涵盖在了储能的范畴里,通过不同形式的能源存储,将电力、热力、交通、油气等网络互连,是能源综合利用,多能互补利用的关键,储能的应用范围将扩大。
 UPS是一种含有储能装置,以逆变器为主要组成部分的恒压、恒频的不间断电源,其主要作用是通过UPS系统对电子设备可靠而不间断地进行供电。根据使用情况的不同,UPS可转换为四种不同的工作方式:正常运行方式、电池工作方式、旁路运行方式和旁路维护方式。
  
  一、正常运行方式
  
  不断电系统的供电原理是当市电正常时,机器会将市电的交流电转换为直流电,而后对电池充电,以备电力中断时使用;这里跟各位强调的是不断电系统并不是停电时才会动作,像是遇到电压过低或过高、瞬间突波等,足以影响设备正常运转的电力品质时,不断电系统均会动作,提供设备稳定且干净的电力。
  
  当市电正常供电时,市电经滤波回路后,分为两个回路动作,其一是经由充电回路对电池组充电,另一个则是经整流回路,作为逆变器的输入,再经过逆变器的转换提供电力给负载使用;由此可知,在线式不断电系统的输出完全由逆变器来供应,不论市电电力品质如何,其输出均是稳定而不受任何影响。
  
  二、电池工作方式
  
  一旦市电发生异常时,将储存于电池中的直流电转换为交流电,此时逆变器的输入改由电池组来供应,逆变器持续提供电力,供给负载继续使用,达到不断电的功能。不断电系统的电力来源是电池,而电池的容量是有限的,不断电系统不会像市电一般无限制的供应,不论多大容量的不断电系统,在其满载的的状态下,其所供电的时间必定有限,若要延长放电时间,须购买长时间型不断电系统。
  
  三、旁路运行方式
  
  当在线式UPS超载、旁路命令(手动或自动)、逆变器过热或机器故障,UPS一般将逆变输出转为旁路输出,即由市电直接供电。由于旁路时,UPS输出频率相位需与市电频率相位相同,采用锁相同步技术确保UPS输出与市电同步。旁路开关双向可控硅并联工作方式,解决了旁路切换时间问题,真正做到了不间断切换,控制电路复杂,一般应用在中大功率UPS上。如果在过载时,必须人为减少负载,否则旁路短路器会自动切断输出。
  
  四、旁路维护方式
  
  当UPS进行检修时,通过手动旁路保证负载设备的正常供电,当维修操作完成后,重新启动UPS,UPS转为正常运行。极低的维护率,MTTR为15万小时,极大地提高UPS可用性。储能电站,集中式新能源基地配置《指导意见》“推动在集中式新能源发电基地配置适当规模的储能电站,实现储能系统与新能源、电网的协调优化运行”。

目前,与集中式风光电站相结合的储能示范项目,基本都建设在某一个电站,《指导意见》提出了一条完全不同的思路,这也代表着经过几年示范运行,决策部门也在思考储能的佳配置。储能配置在发电基地,更能统筹协调多个电站与电网协调优化运行,避免资源配置上的浪费,在储能成本较高的现状下,更加经济可行。建设在单一风光电站的储能项目,电网对其调度管理有限,多将其视为电厂的一项设备与电厂一起管理,不利于明晰储能的功能、计算储能的价值。在发电基地配置,与单个风光电站相对独立,储能作为一项电力资源为电网提供电力服务存在了可能性,也为探讨储能的价值实现、经济收益计算、商业模式建立创造了条件。有专家表示,如果在新能源发电基地配置储能电站,5-10%的容量基本能满足风光调节的需求。根据《可再生能源发展“十二五”规划》,我国风电装机到2020年,将达200GW,按此简单计算,集中式风电站将给储能带来的潜在市场空间为10-20GW,储能发展潜力巨大。
3999639165.jpg

Model

NominalVoltage
(v)

NominalCapacity
(Ah)

Dimensions

Ht.Over Terminal

Weight Approx(kg)

Terminals

Accessories

L

W

H

in

mm

in

kg

lb

GEL100-2

2

100

6.73

171

2.83

72

8.07

205

8.27

210

6

13.22

B05

·  download

GEL200-2

200

6.81

173

4.37

111

12.95

329

14.37

365

16.4

36.15

·  download

GEL300-2

300

5.94

151

12.99

330

14.41

366

24.6

54.22

·  download

GEL400-2

400

8.31

211

6.93

176

14.45

367

31.8

70.09

·  download

GEL500-2

500

9.49

241

6.77

172

13.03

331

39

85.96

·  download

GEL600-2

600

11.85

301

6.89

175

49.2

108.44

·  download

GEL800-2

800

16.14

410

65.6

144.58

·  download

GEL1000-2

1000

18.7

475

12.91

328

80

176.32

·  download

GEL1500-2

1500

15.79

401

13.82

351

13.46

342

14.88

378

118

260.07


GEL2000-2

2

2000

19.33

491

13.82

351

13.54

344

15.08

383

159

350.44

B05

·  download

 

What are deep cyclebatteries?
Deep-cycle batteriestypically feature thick plates with a high-density active material.The thick battery plates allow for reserve energy to be stored deepwithin the battery plate and released during slow discharge such astrolling or electronic instrument use. The high-density activematerial remains within the batteries' plate/grid structure longer,resisting the normal degradation found in cycling conditions. Theyare typically used where the battery is discharged to great extentand then recharged such as a battery powered trolling motor on afishing boat.

 正确地安装、运行和维护蓄电池
  
  错误的安装及维护会缩短蓄电池的使用寿命。所谓良好的维护措施,就是要给蓄电池提供良好的通风条件,温度尽可能控制在77华氏度左右,确保到达所有电池组中蓄电池的空气温度都在3华氏度左右,还应该确保电池组中的一些蓄电池的老化速度不会比其它电池快太多。
  
  这是为什么呢?将不同使用时间和内电阻大小不同的蓄电池混合使用会加速其老化过程。对蓄电池进行定期检查可以解决诸如注液电池连接松散及密封不良等多种问题,而这些问题会导致设备被腐蚀,甚至是酿成火灾。
  
  数据中心管理者们还应该随时关注蓄电池的放电状态。如果一台空电池在48小时内没有被充电,这台电池基本上会报废。对蓄电池过度放电会导致重复充电问题,而过度放电也会降低蓄电池的使用寿命。
  
  对UPS蓄电池容量进行监测
  
  受到腐蚀等因素的影响,蓄电池的内电阻会逐渐增大,当其增加量达到30%之后,就该对其进行替换了。通过容量测试,这个问题很容易被发现,就像大多数制造商所讲的那样,当一台蓄电池容量降到它原始容量的80%之后,就应该更换了。
  
  用户在对其蓄电池性能和容量进行测试时,应该基于IEEE标准,好是IEEE1180或IEEE450.
  
  考虑将飞轮UPS与蓄电池UPS配合使用
  
  如果将飞轮UPS和蓄电池UPS配合使用,飞轮就可以处理一些段时间的或是较频繁的停电事故,从而减少蓄电池的电力循环次数。
  
  AustinCBSKEYE-TV首席工程师ArtSmith表示,他所利用的ActivePower飞轮能将蓄电池的寿命延长两年。
  
  “电源中时常会有一些‘浪涌’和‘峰值’,我希望飞轮可以对电源进行‘过滤’,”他说,“飞轮电源可以将其过滤,如果让其进入蓄电池,就会削减电池的使用寿命。”

 报告援引国外的数据称,与国外主要发达国家相比,中国在发电环节碳排放总量远远高于日本、德国、法国,单位电量发电环节碳排放超过世界主要发达国家。2008年发电环节,中国每万千瓦时碳排放为2.01吨,是美国的1.22倍、德国的1.5倍、日本的1.7倍、法国的12.6倍。而2001年以来,中国电网输电线路线损率呈现不断下降趋势。数据显示,2009年电网输电线路损失率比上年减少0.24个百分点,降为6.55%。根据测算,由于中国每年发电总量不断增加,电力输送环节碳排放总量亦呈现上升趋势,与世界主要发达国家相比,2007年在电力输送环节,中国碳排放要高于法国、德国、日本,略低于美国。

    单位电量输电环节碳排放超过世界主要发达国家,2007年电力输送环节,中国每万千瓦时碳排放为0.049吨,是美国的1.3倍、德国的2.05倍、日本的2.26倍、法国的11倍。

  4009077531.jpg

所属分类:中国电工电气网 / 蓄电池
关于山东恒泰正宇电源科技有限公司销售部商铺首页 | 更多产品 | 联系方式 | 黄页介绍
法定代表人杨善敏
经营范围APC、艾默生等UPS电源,CSB、理士、西恩迪、松下、汤浅等蓄电池、机柜,稳压电源、电解电源等
公司简介山东恒泰正宇电源科技有限公司成立于2019年,公司地址坐落于北京中关村科技园区内,是APCUPS电源北方地区合作伙伴,是深圳山特北京区银牌代理。主要经营计算机机房设备(物理基础设施),APC北方地区代理,深圳山特济南代理商,经销艾默生UPS电源,希世比(CSB)电池济南地区代理商,松下电池济南地区代理商。公司拥有专业电器安装人员和施工队伍,承接专业机房配电及布线系统,机房运维,供电及制冷方案设计, ...
公司新闻
我们的其他产品
顺企网 | 公司 | 黄页 | 产品 | 采购 | 资讯 | 免费注册 轻松建站
免责声明:本站信息由山东恒泰正宇电源科技有限公司销售部自行发布,交易请核实资质,谨防诈骗,如有侵权请联系我们   法律声明  联系顺企网
© 11467.com 顺企网 版权所有
ICP备案: 粤B2-20160116 / 粤ICP备12079258号 / 粤公网安备 44030702000007号 / 互联网药品信息许可证:(粤)—经营性—2023—0112