EV805A-A Discover 深循环 8V 235AH 工业电池 价格及参数
EV805A-A![]()
Discover® DRY CELL Traction Industrial batteries outperform traditional Flooded, AGM, and Gel deep-cycle batteries in demanding traction and industrial applications. The batteries are designed to deliver a long runtime, high operating current and withstand deep discharge and are ideal for powering equipment that is used multiple times a day.
DRY CELL Traction Industrial batteries have been used and trusted for more than ten years by the world’s largest industrial Original Equipment Manufacturers. Specific charge algorithms are available that support optimal battery performance and longevity.



NOTE 1: Dimensions have a ±2 mm (0.08 in) tolerance. Weights may vary.
NOTE 2: Refer to terminal guide on website for torque values.
NOTE 3: Extra considerations must be given when designing systems for use at maximum temperatures.
NOTE 4: Internal Resistance is approximate.
3 HR: 1.70VPC; 5 HR: 1.75VPC; 20 HR: 1.80VPC. All at 25°C/77°F
Minutes of Discharge![]()
![]()
![]()
![]()
![]()
![]()
![]()
FEATURES
HYDRO POLYMER
Organic capillary separators with hydro polymer electrolytes resist dry-out and prevent thermal runaway
Maintains performance characteristics over operational life
ENHANCED ALLOYS
Thick plates with graphite enhanced alloys deliver maximum runtime over operational life
CARBON BOOST
Carbon additives to increase duty cycle performance, charge acceptance and partial state of charge operation
AUTOMATED THROUGH-THE-PARTITION WELD
Improved intercell weld consistency, and less lead waste than manual welding process (key models)
Supports higher current loads and lowers internal resistance
POLYPROPYLENE CASE
High heat resistance and durability (key industry models)
High precision pressure relief valves reduce water loss and extend life
Integrated flame arrestors prevent fire and explosion
BENEFITSENHANCED RUNTIME
High amp hour capacity
High operational voltage over lifetime
Delivers 80% DoD above 1.9 VPC
EXTENDED SERVICE LIFE
Long life superior to deep-cycle FLA / AGM / Gel batteries
550+ cycles 70% DoD (IEC 254-1 Traction Lead-Acid)
350+ cycles DoD (DIN 43 539 VRLA)
RESILIENCE
Partial stage of charge operation superior to AGM
Intense duty cycling superior to AGM / Gel
Overcharge and over-discharge resilience superior to AGM
Compatible with AGM / Gel semi-traction charge profile
EXTREME TEMPERATURES
High temperature life superior to AGM
Low temperature operation superior to FLA / AGM / Gel batteries
EXTREME VIBRATION RESISTANCE
Vibration resistance superior to AGM / Gel
Shock tested (IEC 61373, DIN EN 61373, SAE J537)
OEM TRUSTED
Exceeds OEM specifications
Innovative technology
Global service and support
RELIABLE AND SAFE
Valve Regulated Lead-Acid, Dry Cell AGM
Maintenance-free, nonspillable, no-gassing
Spark and explosion tested (SAE J1495)
UALITY
Discover® manufacturing facilities are fully certified to ISO 9001/14001 and OSHA 18001 standards.
Designed in accordance with and published in compliance with applicable standards, including:
IEC 60254-1. Lead-Acid Traction
DIN 43 539. VRLA
SAE J537. Storage
UL, CE Health Safety Certified
SHIPPING CLASSIFICATIONClassified as a nonspillable battery
Without restriction for transport by Sea (IMDG amendment 27)
Without restriction for transport by Air (IATA/ICAO provision 67)
Without restriction for transport by Ground (STB, DOT-CFR-HMR49)
Temperature Effects on Capacity








Due to self-discharge characteristics of lead-acid battery technologies, batteries should be top charged within 6 months of storage to ensure optimum performance, prevent sulphation and permanent capacity loss.
Charge profile recommendations correspond to battery voltages at 25°C (77°F). For temperatures below, adjust +5mVPC/°C (+3mVPC/°F). Temperatures above, adjust -5mVPC/°C (-3mVPC/°F). Temperature compensated charging helps ensure optimum battery runtime and life performance.
Charge profile recommendations depend on application and charger. IUI (or IUI with Pulse) is appropriate for applications that require frequent and deep discharges. IUU is appropriate for applications that are on standby and cycled less frequently.
IUI with Pulse algorithm uses a pulse termination criterion. The finish current is pulsed on and off in order to keep the battery voltage at a minimum while still reaching target overcharge. If average VPC exceeds U4 and the charger output has been on for more than 30 seconds, the output is shut off until VPC falls to U3.
IUI Charge Profile (if applicable), may have a continuous float phase added (2.27VPC).
| 成立日期 | 2013年05月20日 | ||
| 注册资本 | 2000 | ||
| 主营产品 | 蓄电池、锂电池、牵引蓄电池、升降平台电池、太阳能电池、光伏电池、UPS电源、EPS蓄电池、柴油发电机电池、直流屏电池、启动电池、进口蓄电池,UPS不间断电源,逆变器,充电器, | ||
| 经营范围 | 技术开发;销售计算机、软件及辅助设备、文化用品、电子产品、五金交电、通讯设备、日用品、塑料制品、仪器仪表。(依法须经批准的项目,经相关部门批准后依批准的内容开展经营活动) | ||
| 公司简介 | LEGACYPOWER(UK)LIMITED是享誉世界的电源电池制造公司。这家创立于英国工业重镇伯明翰的老牌电池公司始建于1921年,迄今为止已经生产了上千种各种类型各种型号的狮克(LEGACY)蓄电池、电源配件以及各种电线电缆产品。经过近百年的发展,已成为欧洲乃至世界工业电源电池的。北京狮克电源科技有限公司为LEGACYPOWER(UK)LIMITED中国营销总部,全权负责中国市场的产品销售、售 ... | ||